Filter Results By:

Products

Applications

Manufacturers

Showing results: 166 - 180 of 268 items found.

  • High-Speed High-Voltage Power Amplifier

    Model 10/40A-HS - TREK, INC.

    The Model 10/40A-HS is a DC-stable, high-speed, high-voltage power amplifier used in industrial and research applications. It features an all-solid-state design for high slew rate, wide bandwidth and low-noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This type of output is essential to achieve an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.

  • Preamplifiers

    A.H.Systems, Inc.

    A.H. Systems'' Preamplifier line is an excellent choice with a rugged design, no hassles with soldering your own power leads and they improve overall system sensitivity by at least 20 dB. All of A.H. Systems'' Preamplifiers come with a 12-volt (or 15-volt) DC regulated power source. A low voltage indicator confidently allows you to power the amplifier with your own external 12-volt DC battery. This makes it a convenient choice for field measurements. See table below for amplifier specifications.

  • Energized Cable Sensor

    Hubbell Power Systems Inc

    The purpose of the Energized Cable Sensor is to allow the lineman to readily determine whether a URD cable is energized. The sensor consists of an amplifier which is designed to give a meter reading when the small AC voltage between the semi-conductive sheath and the concentric neutral of the energized URD cable is applied to the test probe. The amplifier is housed in a rugged phenolic case. Sensor may be used to check for energized condition on concentric-neutral cable below an elbow without test points. At cable mid-span (left), hose clamps bridge all strands of concentric neutral at the test location. Sensor’s neutral lead clips to one of the hose clamps. Tip on probe lead contacts only semi-conductive cable sheath to test for voltage presence.

  • Transimpediance Amplifiers

    Gamma Scientific Inc.

    The UDT TRAMP products are transimpedance amplifier (current-to-voltage) instruments that provide a low input impedance to accurately measure the short circuit current of phototransducers such as silicon and germanium photodetectors, vacuum photodiodes and photomultiplier tubes. The range includes the economically priced TRAMP, and for ultra precision and accuracy, the TIA-3000.

  • Light-to-Analog Sensors (Voltage)

    Renesas Electronics Corp.

    Renesas' light-to-voltage silicon optical sensors combine a photodiode array, a non-linear current amplifier and a micropower op amp on a single monolithic IC. Applications for these devices include display backlight control, keypad dimming, anti-glare mirror systems, and industrial and medical light sensing applications.

  • Peripheral Differential Amplifier

    Ivium Technologies B.V.

    The Peripheral Differential Amplifier (PDA) module allows the simultaneous recording of differential bipolar high-ohmic external voltages, such as reference or pH meters. The PDA has 8 differential input channels, and it is stackable up to units with a total of 64 channels. The PDA module is powered from the grid via an adapter.

  • AC Source

    AFC - Intepro Systems

    The AFC Series products are single and three phase AC Power sources ranging from 0.5kVA to 2000kVA. This AFC series has a continuous and adjustable output voltage between 5~300V. This allows for quick and convenient 3 scales of preset voltage for high and low voltage simulation. Power is supplied by state-of-the-art IBGT pulse width-modulated power amplifiers resulting in highly efficient power conversion, compact design and maximized performance. With up to 90% efficiency the AFC minimizes heat dissipation so less infrastructure cooling is required.

  • Single Phase Lock-In Amplifier

    SR510 - Stanford Research Systems, Inc.

     The SR510 and SR530 are analog lock-in amplifiers which can measure AC signals as small as nanovolts in the presence of much larger noise levels. Both the single phase SR510 and the dual phase SR530 have low-noise voltage and current inputs, high dynamic reserve, two stages of time constants, and an internal oscillator. 

  • Gated Integrator | Boxcar Averager

    GIA100 - Artifex Engineering GmbH & Co. KG

    The GIA100 gated integrator employs dual monolithic switched integrators. When paired with a photodiode, the boxcar amplifier measures the energy of single optical pulses. The GIA100 design results in very low leakage error, charge injection error and pickup. The precision input stage may be configured for current or voltage inputs.

  • Charge Amplifier

    ZET 440 - ZETLAB Company

    Charge amplifier ZET 440 for piezoelectric detectors is intended for:*amplification and conversion of output signals of primary piezoelectric transducers with charge output;*amplification and conversion of output signals of primary transducers with the IEPE type in-built electronics to voltage;*gain ratios: 1, 10, 100;*LPF: 0.1, 1, 10 Hz

  • Current Sense Amplifiers

    Analog Devices Inc.

    Analog Devices’ current sense amplifiers offer excellent performance for a wide array of automotive and power management applications. These devices accurately amplify small voltages in the presence of large common-mode voltage, and provide high bandwidth, as well as level shifting and bidirectional capability. Excellent dc and ac accuracy over a wide temperature range from –40°C to +125°C minimizes errors in your measurement loop while not sacrificing on cost and package size.

  • High-Voltage Power Amplifier

    Model 50/12 - TREK, INC.

    The Model 50/12 is a DC-stable, high-voltage power amplifier featuring an all solid-state design for high slew rate, wide bandwidth, and low-noise operation. It is designed to provide precise control of output voltages in the range of 0 to ±50 kV DC or peak AC with an output current range of 0 to ±12 mA DC or peak AC.

  • Low Noise Triple Band Voltage Controlled Oscillator

    Teledyne RF & Microwave

    This Low Noise Triple Band Voltage Controlled Oscillator was designed to meet a specific customer requirement. The VCO cover the 3300 to 4700 MHz frequency range in three bands. The output power is +9 to +12 dBm with an integrated buffer amplifier to minimize load pulling. The three bands are selected using standard TTL control.

  • RF Power Amplifiers

    Pasternack Enterprises, Inc.

    RF power amplifier category from Pasternack have components packaged in a hermetically-sealed metal enclosures and exhibit outstanding performance in high gain, gain flatness, high linearity and wide dynamic range. RF power amplifiers have excellent performance by using a hybrid microwave integrated circuit design and advanced GaAs pHEMT components. These SMA power amplifier modules are unconditionally stable and include built-in voltage regulation, bias sequencing, and reverse bias protection for added reliability.RF power amplifier over-voltage protection is installed externally for easy repair. These high reliability radio frequency power amps are fully matched internally for 50 Ohm input and output. This 50 Ohm power amplifier matching helps eliminates the need for any additional sensitive external RF tuning components.Our power amps are ideally suited for high linearity applications. These radio frequency power amplifiers offer small signal gain over a temperature range. The Pasternack RF power amplifiers have excellent gain flatness ranges and the IP3 output performance.Most all Pasternack RF power amplifiers are EAR99

  • Temperature Sensor

    ITS-7025 - Innovative Technical Systems

    The ITS-7025 Temperature Sensor was developed to monitor the temperature of liquid-cooled klystron amplifiers. The sensor is designed to clamp directly to the cooling pipe and provide an analog voltage output from 0 to 10 VDC corresponding to 0 to 100 degC with 2 degC accuracy. Two analog outputs are provided; one for connection to a remote data acquisition system, and a second for local service monitoring. A single +28 VDC (other voltages available) powers the sensor which draws less than 100 uA.

Get Help